安全信息
GHS Symbol
WGK Germany | 3 |
Hazard Codes |
9 |
Hazard statements | |
- H341 Suspected of causing genetic defects 怀疑导致遗传性缺陷
- H350 May cause cancer 可能致癌
- H400 Verytoxictoaquaticlife 对水生生物毒性非常大。
- H410 Verytoxictoaquaticlifewithlonglastingeffects 对水生生物毒性非常大并具有长期影响。
|
Personal Protective Equipment |
dust mask type N95 (US), Eyeshields, Gloves, type P2 (EN 143) respirator cartridges |
RTECS | GC0700000 |
Precautionary statements | |
- P273 Avoid release to the environment. 避免释放到环境中。
- P405 Store locked up. 上锁保管。
- P501 Dispose of contents/container to..… 处理内容物/容器.....
- P280 Wear protective gloves/protective clothing/eye protection/face protection. 戴防护手套/防护服/眼睛的保护物/面部保护物。
- P318
- P203
- P391 Collect spillage. Hazardous to the aquatic environment 收集对水环境有危害的泄漏物。
|
Signal word |
Danger |
UN Number |
3077 |
Safety Statements | |
- S60 This material and its container must be disposed of as hazardous waste 该物质及其容器必须作为危险废物处置;
- S61 Avoid release to the environment. Refer to special instructions/safety data sheet 避免释放到环境中,参考特别指示/安全收据说明书;
- S45 In case of accident or if you feel unwell seek medical advice immediately (show the label where possible) 发生事故时或感觉不适时,立即求医(可能时出示标签);
- S53 Avoid exposure - obtain special instructions before use 避免接触,使用前获得特别指示说明;
|
Risk Statements | |
- R68 Possible risk of irreversible effects 可能有不可挽回的作用的危险
- R45 May cause cancer 可能致癌
- R50/53
|
Packing Group | III |
Hazard Class | 9 |
Storage condition |
2-8°C
{LY} 2-8°C
{} {LY} 2-8°C
{} {} {LY} 2-8°C
{} {} {} {LY} 2-8°C
{} {} {} {} {LY} 2-8°C
{} {} {} {} {} {LY} 2-8°C
{} {} {} {} {} {} {LY} 2-8°C
{} {} {} {} {} {} {} {LY} 2-8°C
{} {} {} {} {} {} {} {} {LY} 2-8°C
{} {} {} {} {} {} {} {} {} {LY} 2-8°C
{} {} {} {} {} {} {} {} {} {} {LY} 2-8°C
室温储存 |
TYPE OF TEST : TDLo - Lowest published toxic dose
ROUTE OF EXPOSURE : Administration onto the skin
SPECIES OBSERVED : Rodent - mouse
DOSE/DURATION : 3600 ug/kg
TOXIC EFFECTS :
Tumorigenic - neoplastic by RTECS criteria
Skin and Appendages - tumors
REFERENCE :
CNREA8 Cancer Research. (Public Ledger Building, Suit 816, 6th & Chestnut
Sts., Philadelphia, PA 19106) V.1- 1941- Volume(issue)/page/year:
38,1831,1978
TYPE OF TEST : TD - Toxic dose (other than lowest)
ROUTE OF EXPOSURE : Administration onto the skin
SPECIES OBSERVED : Rodent - mouse
DOSE/DURATION : 40 mg/kg/3W-I
TOXIC EFFECTS :
Tumorigenic - equivocal tumorigenic agent by RTECS criteria
Skin and Appendages - tumors
REFERENCE :
CCSUDL Carcinogenesis--A Comprehensive Survey. (Raven Press, 1185 Ave. of
the Americas, New York, NY 10036) V.1- 1976- Volume(issue)/page
TYPE OF TEST : TD - Toxic dose (other than lowest)
ROUTE OF EXPOSURE : Administration onto the skin
SPECIES OBSERVED : Rodent - mouse
DOSE/DURATION : 99 mg/kg/31W-I
TOXIC EFFECTS :
Tumorigenic - equivocal tumorigenic agent by RTECS criteria
Skin and Appendages - tumors
REFERENCE :
CNREA8 Cancer Research. (Public Ledger Building, Suit 816, 6th & Chestnut
Sts., Philadelphia, PA 19106) V.1- 1941- Volume(issue)/page/year:
11,301,1951
TYPE OF TEST : TDLo - Lowest published toxic dose
ROUTE OF EXPOSURE : Subcutaneous
SPECIES OBSERVED : Rodent - mouse
DOSE/DURATION : 200 mg/kg
TOXIC EFFECTS :
Tumorigenic - equivocal tumorigenic agent by RTECS criteria
Tumorigenic - tumors at site of application
REFERENCE :
CNREA8 Cancer Research. (Public Ledger Building, Suit 816, 6th & Chestnut
Sts., Philadelphia, PA 19106) V.1- 1941- Volume(issue)/page/year:
15,632,1955
TYPE OF TEST : LD50 - Lethal dose, 50 percent kill
ROUTE OF EXPOSURE : Intraperitoneal
SPECIES OBSERVED : Rodent - mouse
DOSE/DURATION : >320 mg/kg
TOXIC EFFECTS :
Details of toxic effects not reported other than lethal dose value
REFERENCE :
JJIND8 JNCI, Journal of the National Cancer Institute. (Washington, DC)
V.61-79, 1978-87. For publisher information, see JNCIEQ.
Volume(issue)/page/year: 62,911,1979
TYPE OF TEST : Mutation test systems - not otherwise specified
TEST SYSTEM : Bacteria - Escherichia coli
DOSE/DURATION : 50 mg/L
REFERENCE :
MUREAV Mutation Research. (Elsevier Sc
TYPE OF TEST : DNA adduct
ROUTE OF EXPOSURE : Administration onto the skin
TEST SYSTEM : Rodent - mouse
DOSE/DURATION : 192 umol/kg
REFERENCE :
CRNGDP Carcinogenesis (London). (Oxford Univ. Press, Pinkhill House,
Southfield Road, Eynsham, Oxford OX8 1JJ, UK) V.1- 1980-
Volume(issue)/page/year: 5,231,1984
TYPE OF TEST : Mutation in mammalian somatic cells
TEST SYSTEM : Human Lymphocyte
DOSE/DURATION : 6 umol/L
REFERENCE :
DTESD7 52 Vanderbilt Ave., New York, NY 10017) V.1-15, 1977-87.
Discontinued 52 Vanderbilt Ave., New York, NY 10017) V.1- 1977-
Volume(issue)/page/year: 10,277,1982
TYPE OF TEST : Mutation test systems - not otherwise specified
ROUTE OF EXPOSURE : Intraperitoneal
TEST SYSTEM : Rodent - mouse
DOSE/DURATION : 10 mg/kg
REFERENCE :
EMMUEG Environmental and Molecular Mutagenesis. (Alan R. Liss, Inc., 41 E.
11th St., New York, NY 10003) V.10- 1987- Volume(issue)/page/year:
19,259,1992
TYPE OF TEST : Mutation in microorganisms
TEST SYSTEM : Bacteria - Salmonella typhimurium
DOSE/DURATION : 5 ug/plate
REFERENCE :
MUREAV Mutation Research. (Elsevier Science Pub. B.V., POB 211, 1000 AE
Amsterdam, Netherlands) V.1- 1964- Volume(issue)/page/year: 156,61,1985
TYPE OF TEST : Morphological transformation
TEST SYSTEM : Rodent - hamster Embryo
DOSE/DURATION : 10 mg/L
REFERENCE :
IJCNAW International Journal of Cancer. (International Union Against
Cancer, 3 rue du Conseil- General, 1205 Geneva, Switzerland)