安全信息
WGK Germany | 2 |
GHS Symbol
Precautionary statements | |
- P280 Wear protective gloves/protective clothing/eye protection/face protection. 戴防护手套/防护服/眼睛的保护物/面部保护物。
- P305+P351+P338
|
Hazard statements | |
- H318 Causes serious eye damage 严重伤害眼睛
|
Hazard Codes |
Xi |
RTECS | TI4950000 |
Personal Protective Equipment |
dust mask type N95 (US), Eyeshields, Gloves |
Signal word |
Danger |
Safety Statements | |
- S26 In case of contact with eyes, rinse immediately with plenty of water and seek medical advice 眼睛接触后,立即用大量水冲洗并征求医生意见;
- S39 Wear eye/face protection 戴眼睛/面孔保护装置;
|
Risk Statements | |
- R41 Risk of serious damage to eyes 有严重损伤眼睛的危险
|
Warnings |
IRRITANT |
TYPE OF TEST : LCLo - Lowest published lethal concentration
ROUTE OF EXPOSURE : Inhalation
SPECIES OBSERVED : Rodent - rat
DOSE/DURATION : 4400 mg/m3/4H
TOXIC EFFECTS :
Sense Organs and Special Senses (Olfaction) - effect, not otherwise
specified
Lungs, Thorax, or Respiration - other changes
REFERENCE :
JACTDZ Journal of the American College of Toxicology. (Mary Ann Liebert,
Inc., 1651 Third Ave., New York, NY 10128) V.1-12, 1982-1993. Discontinued.
Volume(issue)/page/year: 4(1),219,1985
TYPE OF TEST : LD50 - Lethal dose, 50 percent kill
ROUTE OF EXPOSURE : Oral
SPECIES OBSERVED : Rodent - rat
DOSE/DURATION : 4700 mg/kg
TOXIC EFFECTS :
Behavioral - somnolence (general depressed activity)
Behavioral - ataxia
Gastrointestinal - changes in structure or function of salivary glands
REFERENCE :
TXAPA9 Toxicology and Applied Pharmacology. (Academic Press, Inc., 1 E.
First St., Duluth, MN 55802) V.1- 1959- Volume(issue)/page/year:
51,197,1979
TYPE OF TEST : Mutation test systems - not otherwise specified
TEST SYSTEM : Bacteria - Escherichia coli
DOSE/DURATION : 1 mmol/L
REFERENCE :
MUREAV Mutation Research. (Elsevier Science Pub. B.V., POB 211, 1000 AE
Amsterdam, Netherlands) V.1- 1964- Volume(issue)/page/year: 231,205,1990
TYPE OF TEST : Sister chromatid exchange
TEST SYSTEM : Rodent - hamster Lung
DOSE/DURATION : 78 umol/L
REFERENCE :
MUREAV Mutation Research. (Elsevier Science Pub. B.V., POB 211, 1000 AE
Amsterdam, Netherlands) V.1- 1964- Volume(issue)/page/year: 249,55,1991
TYPE OF TEST : Mutation in microorganisms
TEST SYSTEM : Bacteria - Klebsiella pneumoniae
DOSE/DURATION : 5 umol/L
REFERENCE :
MUREAV Mutation Research. (Elsevier Science Pub. B.V., POB 211, 1000 AE
Amsterdam, Netherlands) V.1- 1964- Volume(issue)/page/year: 89,269,1981
TYPE OF TEST : Mutation in microorganisms
TEST SYSTEM : Bacteria - Salmonella typhimurium
DOSE/DURATION : 500 ng/plate
REFERENCE :
MUREAV Mutation Research. (Elsevier Science Pub. B.V., POB 211, 1000 AE
Amsterdam, Netherlands) V.1- 1964- Volume(issue)/page/year: 68,251,1979
TYPE OF TEST : Mutation in mammalian somatic cells
TEST SYSTEM : Rodent - hamster Ovary
DOSE/DURATION : 10 mg/L
REFERENCE :
MUREAV Mutation Research. (Elsevier Science Pub. B.V., POB 211, 1000 AE
Amsterdam, Netherlands) V.1- 1964- Volume(issue)/page/year: 68,251,1979
TYPE OF TEST : Morphological transformation
TEST SYSTEM : Rodent - hamster Embryo
DOSE/DURATION : 1250 ug/L
REFERENCE :
MUREAV Mutation Research. (Elsevier Science Pub. B.V., POB 211, 1000 AE
Amsterdam, Netherlands) V.1- 1964- Volume(issue)/page/year: 68,251,1979