安全信息
WGK Germany | 2 |
RTECS | LZ6650000 |
Personal Protective Equipment |
Eyeshields, Gloves, type N95 (US), type P1 (EN143) respirator filter |
TYPE OF TEST : LD50 - Lethal dose, 50 percent kill
ROUTE OF EXPOSURE : Intracerebral
SPECIES OBSERVED : Rodent - mouse
DOSE/DURATION : 2910 mg/kg
TOXIC EFFECTS :
Details of toxic effects not reported other than lethal dose value
REFERENCE :
USXXAM United States Patent Document. (U.S. Patent Office, Box 9,
Washington, DC 20231) Volume(issue)/page/year: #4001323
TYPE OF TEST : LD50 - Lethal dose, 50 percent kill
ROUTE OF EXPOSURE : Intraperitoneal
SPECIES OBSERVED : Rodent - mouse
DOSE/DURATION : 9950 mg/kg
TOXIC EFFECTS :
Details of toxic effects not reported other than lethal dose value
REFERENCE :
USXXAM United States Patent Document. (U.S. Patent Office, Box 9,
Washington, DC 20231) Volume(issue)/page/year: #4001323
TYPE OF TEST : LD50 - Lethal dose, 50 percent kill
ROUTE OF EXPOSURE : Intracerebral
SPECIES OBSERVED : Rodent - rat
DOSE/DURATION : 135 mg/kg
TOXIC EFFECTS :
Brain and Coverings - recordings from specific areas of CNS
Behavioral - anticonvulsant
Behavioral - changes in motor activity (specific assay)
REFERENCE :
RADLAX Radiology. (Radiological Soc. of North America, 20th & Northampton
Sts., Easton, PA 18042) V.1- 1923- Volume(issue)/page/year: 140,713,1981
TYPE OF TEST : LD50 - Lethal dose, 50 percent kill
ROUTE OF EXPOSURE : Intravenous
TYPE OF TEST : LD50 - Lethal dose, 50 percent kill
ROUTE OF EXPOSURE : Intravenous
SPECIES OBSERVED : Rodent - rabbit
DOSE/DURATION : 21763 mg/kg
TOXIC EFFECTS :
Details of toxic effects not reported other than lethal dose value
REFERENCE :
ARASA5 Acta Radiologica, Supplementum. (Acta Radiologica, POB 7449, S-10391
Stockholm, Sweden) No.1- 1921- Volume(issue)/page/year: 335,5,1973
{h
TYPE OF TEST
TYPE OF TEST : TDLo - Lowest published toxic dose
ROUTE OF EXPOSURE : Intravenous
SPECIES OBSERVED : Rodent - rat
DOSE : 54008 mg/kg
SEX/DURATION : female 7-17 day(s) after conception
TOXIC EFFECTS :
Reproductive - Fertility - pre-implantation mortality (e.g. reduction in
number of implants per female; total number of implants per corpora lutea)
Reproductive - Fertility - other measures of fertility
REFERENCE :
NIIHAO Nichidoku Iho. Japanese-German Medical Reports. (Nihon Scheringu
K.K, Gakujutsubu, 6-64, Nishimiyahara, 2-chome, Yodogawa-ku, Osaka 532,
Japan) V.1- 1956- Volume(issue)/page/year: 24,287,1979
TYPE OF TEST : TDLo - Lowest published toxic dose
ROUTE OF EXPOSURE : Intraperitoneal
SPECIES OBSERVED : Rodent - rat
DOSE : 11456 mg/kg
SEX/DURATION : female 1-7 day(s) after conception
TOXIC EFFECTS :
Reproductive - Fertility - pre-implantation mortality (e.g. reduction in
number of implants per female; total number of implants per corpora lutea)
REFERENCE :
NIIHAO Nichidoku Iho. Japanese-German Medical Reports. (Nihon Scheringu
K.K, Gakujutsubu, 6-64, Nishimiyahara, 2-chome, Yodogawa-ku, Osaka 532,
Japan) V.1- 1956- Volume(issue)/page/year: 24,277,1979
TYPE OF TEST : TDLo - Lowes
TYPE OF TEST : TDLo - Lowest published toxic dose
ROUTE OF EXPOSURE : Intraperitoneal
SPECIES OBSERVED : Rodent - rat
DOSE : 34369 mg/kg
SEX/DURATION : female 1-7 day(s) after conception
TOXIC EFFECTS :
Reproductive - Effects on Embryo or Fetus - fetal death
REFERENCE :
NIIHAO Nichidoku Iho. Japanese-German Medical Reports. (Nihon Scheringu
K.K, Gakujutsubu, 6-64, Nishimiyahara, 2-chome, Yodogawa-ku, Osaka 532,
Japan) V.1- 1956- Volume(issue)/page/year: 24,277,1979