安全信息
WGK Germany | 3 |
GHS Symbol
Precautionary statements | |
- P264 Wash hands thoroughly after handling. 处理后要彻底洗净双手。
- P260 Do not breathe dust/fume/gas/mist/vapours/spray. 不要吸入粉尘/烟/气体/烟雾/蒸汽/喷雾。
- P301+P310
- P284 Wear respiratory protection.? 佩戴呼吸保护装置。
- P302+P350
- P280 Wear protective gloves/protective clothing/eye protection/face protection. 戴防护手套/防护服/眼睛的保护物/面部保护物。
|
RTECS | XW5886000 |
Signal word |
Danger |
Personal Protective Equipment |
Eyeshields, Faceshields, full-face particle respirator type N100 (US), Gloves, respirator cartridge type N100 (US), type P1 (EN143) respirator filter, type P3 (EN 143) respirator cartridges |
TYPE OF TEST : LD50 - Lethal dose, 50 percent kill
ROUTE OF EXPOSURE : Intravenous
SPECIES OBSERVED : Rodent - mouse
DOSE/DURATION : 200 ug/kg
TOXIC EFFECTS :
Peripheral Nerve and Sensation - fasciculations
Behavioral - tremor
Lungs, Thorax, or Respiration - dyspnea
REFERENCE :
TOXIA6 Toxicon. (Pergamon Press Ltd., Headington Hill Hall, Oxford OX3 OBW,
UK) V.1- 1962- Volume(issue)/page/year: 20,457,1982
TYPE OF TEST : LD50 - Lethal dose, 50 percent kill
ROUTE OF EXPOSURE : Intraperitoneal
SPECIES OBSERVED : Rodent - mouse
DOSE/DURATION : 200 ug/kg
TOXIC EFFECTS :
Peripheral Nerve and Sensation - fasciculations
Behavioral - tremor
Lungs, Thorax, or Respiration - dyspnea
REFERENCE :
TOXIA6 Toxicon. (Pergamon Press Ltd., Headington Hill Hall, Oxford OX3 OBW,
UK) V.1- 1962- Volume(issue)/page/year: 20,457,1982
TYPE OF TEST : LD50 - Lethal dose, 50 percent kill
ROUTE OF EXPOSURE : Oral
SPECIES OBSERVED : Rodent - mouse
DOSE/DURATION : 6600 ug/kg
TOXIC EFFECTS :
Peripheral Nerve and Sensation - fasciculations
Behavioral - tremor
Lungs, Thorax, or Respiration - dyspnea
REFERENCE :
TOXIA6 Toxicon. (Pergamon Press Ltd., Headington Hill Hall, Oxford OX3 OBW,