安全信息
WGK Germany | nwg |
RTECS | XP7320000 |
Personal Protective Equipment |
dust mask type N95 (US), Eyeshields, Gloves
Eyeshields, Gloves, type N95 (US), type P1 (EN143) respirator filter
Faceshields, full-face respirator (US), Gloves, Goggles, multi-purpose combination respirator cartridge (US), type ABEK (EN14387) respirator filter |
Hazard Codes |
C
Xi,F
Xi
C,N |
Hazard statements | |
- H314 Causes severe skin burns and eye damage 导致严重的皮肤灼伤和眼睛损伤
- H290 May be corrosive to metals 可能腐蚀金属。
- H335 May cause respiratory irritation 可能导致呼吸道刺激
- H319 Causes serious eye irritation 严重刺激眼睛
|
Precautionary statements | |
- P310 Immediately call a POISON CENTER or doctor/physician. 立即呼救解毒中心或医生/医师。
- P261 Avoid breathing dust/fume/gas/mist/vapours/spray. 避免吸入粉尘/烟/气体/烟雾/蒸汽/喷雾。
- P280 Wear protective gloves/protective clothing/eye protection/face protection. 戴防护手套/防护服/眼睛的保护物/面部保护物。
- P305+P351+P338
- P273 Avoid release to the environment. 避免释放到环境中。
- P303+P361+P353
- P304+P340+P310
- P201 Obtain special instructions before use. 使用前获取专门指示。
|
Signal word |
Danger
Warning |
Safety Statements | |
- S36/37/39 Wear suitable protective clothing, gloves and eye/face protection 穿戴适当的防护服、手套和眼睛/面保护;
- S26 In case of contact with eyes, rinse immediately with plenty of water and seek medical advice 眼睛接触后,立即用大量水冲洗并征求医生意见;
- S45 In case of accident or if you feel unwell seek medical advice immediately (show the label where possible) 发生事故时或感觉不适时,立即求医(可能时出示标签);
- S16 Keep away from sources of ignition - No smoking 远离火源,禁止吸烟;
- S33 Take precautionary measures against static discharges 对静电采取预防措施;
- S22 Do not breathe dust 不要吸入粉尘;
- S36/37 Wear suitable protective clothing and gloves 穿戴适当的防护服和手套;
- S24/25 Avoid contact with skin and eyes 避免皮肤和眼睛接触;
- S61 Avoid release to the environment. Refer to special instructions/safety data sheet 避免释放到环境中,参考特别指示/安全收据说明书;
|
Packing Group | II |
UN Number |
1759/3260
UN1789
UN3089
UN 3264 8/PG 2 |
Risk Statements | |
- R11 Highly flammable 非常易燃
- R68 Possible risk of irreversible effects 可能有不可挽回的作用的危险
- R50/53
- R37 Irritating to respiratory system 刺激呼吸道
- R43 May cause sensitisation by skin contact 皮肤接触会产生过敏反应
- R34 Causes burns 会导致灼伤
- R36/37/38 Irritating to eyes, respiratory system and skin 对眼睛、呼吸系统和皮肤有刺激性
- R36/38 Irritating to eyes and skin 对眼睛和皮肤有刺激性
- R36/37 Irritating to eyes and respiratory system 对眼睛和呼吸系统有刺激性
- R22 Harmful if swallowed 吞咽有害
|
Hazard Class | 4.1 |
Storage condition |
RT, stored under nitrogen
{LY} RT, stored under nitrogen
Store at room temperature
Store at room temperature, keep dry and cool
{} {LY} RT, stored under nitrogen
{} {} {LY} RT, stored under nitrogen
{} {} {} {LY} RT, stored under nitrogen
{} {} {} {} {LY} RT, stored under nitrogen
{} {} {} {} {} {LY} RT, stored under nitrogen
{} {} {} {} {} {} {LY} RT, stored under nitrogen
{} {} {} {} {} {} {} {LY} RT, stored under nitrogen
{} {} {} {} {} {} {} {} {LY} RT, stored under nitrogen
{} {} {} {} {} {} {} {} {} {LY} RT, stored under nitrogen
{} {} {} {} {} {} {} {} {} {} {LY} RT, stored under nitrogen
{} {} {} {} {} {} {} {} {} {} {} {LY} RT, stored under nitrogen
{} {} {} {} {} {} {} {} {} {} {} {} {LY} RT, stored under nitrogen
{} {} {} {} {} {} {} {} {} {} {} {} {} {LY} RT, stored under nitrogen
{} {} {} {} {} {} {} {} {} {} {} {} {} {} {LY} RT, stored under nitrogen
{} {} {} {} {} {} {} {} {} {} {} {} {} {} {}
{} {} {} {} {} {} {} {} {} {} {} {} {} {} |
TYPE OF TEST : TDLo - Lowest published toxic dose
ROUTE OF EXPOSURE : Implant
SPECIES OBSERVED : Rodent - mouse
DOSE/DURATION : 840 gm/kg
TOXIC EFFECTS :
Tumorigenic - equivocal tumorigenic agent by RTECS criteria
Tumorigenic - tumors at site of application
REFERENCE :
RCOCB8 Research Communications in Chemical Pathology and Pharmacology. (PJD
Pub. Ltd., P.O. Box 966, Westbury, NY 11590) V.1- 1970-
Volume(issue)/page/year: 18,201,1977
TYPE OF TEST : TDLo - Lowest published toxic dose
ROUTE OF EXPOSURE : Implant
SPECIES OBSERVED : Rodent - rat
DOSE/DURATION : 395 gm/kg
TOXIC EFFECTS :
Tumorigenic - equivocal tumorigenic agent by RTECS criteria
Tumorigenic - tumors at site of application
REFERENCE :
RCOCB8 Research Communications in Chemical Pathology and Pharmacology. (PJD
Pub. Ltd., P.O. Box 966, Westbury, NY 11590) V.1- 1970-
Volume(issue)/page/year: 18,201,1977