安全信息
GHS Symbol
WGK Germany | 2 |
Hazard Codes |
6.1
C,N
Xn |
Hazard statements | |
- H351 Suspected of causing cancer 怀疑致癌
- H302 Harmful if swallowed 吞食有害
- H371 May cause damage to organs 可能导致器官损伤
- H314 Causes severe skin burns and eye damage 导致严重的皮肤灼伤和眼睛损伤
- H335 May cause respiratory irritation 可能导致呼吸道刺激
- H400 Verytoxictoaquaticlife 对水生生物毒性非常大。
- H225 Highly flammable liquid and vapour 高度易燃液体和蒸气
- H315 Causes skin irritation 会刺激皮肤
- H336 May cause drowsiness or dizziness 肯能导致嗜睡或头晕
- H319 Causes serious eye irritation 严重刺激眼睛
- H373 May causes damage to organs through prolonged or repeated exposure 长期或频繁接触可能会损伤器官
|
Personal Protective Equipment |
Eyeshields, Faceshields, full-face respirator (US), Gloves, multi-purpose combination respirator cartridge (US) |
RTECS | PA8050000 |
Precautionary statements | |
- P201 Obtain special instructions before use. 使用前获取专门指示。
- P240 Ground/bond container and receiving equipment. 与地面接触/连接集装箱和接受设备。
- P261 Avoid breathing dust/fume/gas/mist/vapours/spray. 避免吸入粉尘/烟/气体/烟雾/蒸汽/喷雾。
- P264 Wash hands thoroughly after handling. 处理后要彻底洗净双手。
- P271 Use only outdoors or in a well-ventilated area.? 只能在室外或通风良好的地方使用。
- P281 Use personal protective equipment as required. 使用所需的个人防护装备。
- P303+P361+P353
- P304+P340
- P305+P351+P338
- P308+P313
- P501 Dispose of contents/container to..… 处理内容物/容器.....
|
Signal word |
Danger
Warning |
Safety Statements | |
- S23 Do not breathe gas/fumes/vapour/spray (appropriate wording to be specified by the manufacturer) 不要吸入气体/烟雾/蒸汽/喷雾;
- S24/25 Avoid contact with skin and eyes 避免皮肤和眼睛接触;
- S36/37 Wear suitable protective clothing and gloves 穿戴适当的防护服和手套;
|
Risk Statements | |
- R36/37/38 Irritating to eyes, respiratory system and skin 对眼睛、呼吸系统和皮肤有刺激性
- R40 Limited evidence of a carcinogenic effect 有限证据表明其致癌作用
- R67 Vapours may cause drowsiness and dizziness 蒸汽可能导致嗜睡和昏厥
|
Storage condition |
储存温度2-8℃
密封避光保存。
充氩保存
0-10°C
0-10
储存温度 2-8°C ,充氩储存 |
UN Number |
1593
1593/1912
UN1593 |
Packing Group | III |
Hazard Class | 3/6.1 |
TYPE OF TEST : TCLo - Lowest published toxic concentration
ROUTE OF EXPOSURE : Inhalation
SPECIES OBSERVED : Rodent - mouse
DOSE/DURATION : 2000 ppm/5H/2Y-C
TOXIC EFFECTS :
Tumorigenic - Carcinogenic by RTECS criteria
Lungs, Thorax, or Respiration - tumors
REFERENCE :
NTPTR* National Toxicology Program Technical Report Series. (Research
Triangle Park, NC 27709) No.206- Volume(issue)/page/year: NTP-TR-306,1986
TYPE OF TEST : TCLo - Lowest published toxic concentration
ROUTE OF EXPOSURE : Inhalation
SPECIES OBSERVED : Rodent - rat
DOSE/DURATION : 3500 ppm/6H/2Y-I
TOXIC EFFECTS :
Tumorigenic - Carcinogenic by RTECS criteria
Endocrine - tumors
REFERENCE :
FAATDF Fundamental and Applied Toxicology. (Academic Press, Inc., 1 E.
First St., Duluth, MN 55802) V.1- 1981- Volume(issue)/page/year:
4,30,1984
TYPE OF TEST : TCLo - Lowest published toxic concentration
ROUTE OF EXPOSURE : Inhalation
SPECIES OBSERVED : Human
DOSE/DURATION : 500 ppm/8H
TOXIC EFFECTS :
Behavioral - euphoria
REFERENCE :
SCIEAS Science. (American Assoc. for the Advancement of Science, 1333 H
St., NW, Washington, DC 20005) V.1- 1895- Volume(issue)/page/year:
176,295,1972
TYPE OF TEST : LC50 - Lethal concentration, 50 percent kill
ROUTE OF EXPOSURE : Inhalation
SPECIES OBSERVED : Rodent - mouse
DOSE/DURATION : 14400 ppm/7H
TOXIC EFFECTS :
Details of toxic effects not reported other than lethal dose value
REFERENCE :
NIHBAZ National Institutes of Health, Bulletin. (Bethesda, MD)
Volume(issue)/page/year: 191,1,1949
TYPE OF TEST : LDLo - Lowest published lethal dose
ROUTE OF EXPOSURE : Intratracheal
SPECIES OBSERVED : Rodent - rat
DOSE/DURATION : 350 mg/kg
TOXIC EFF
TYPE OF TEST : LDLo - Lowest published lethal dose
ROUTE OF EXPOSURE : Subcutaneous
SPECIES OBSERVED : Rodent - rabbit
DOSE/DURATION : 2700 mg/kg
TOXIC EFFECTS :
Details of toxic effects not reported other than lethal dose value
REFERENCE :
QJPPAL Quarterly Journal of Pharmacy & Pharmacology. (London, UK) V.2-21,
1929-48. For publisher information, see JPPMAB. Volume(issue)/page/year:
7,205,1934
TYPE OF TEST : LDLo - Lowest published lethal dose
ROUTE OF EXPOSURE : Intravenous
SPECIES OBSERVED : Mammal - dog
DOSE/DURATION : 200 mg/kg
TOXIC EFFECTS :
Details of toxic effects not reported other than lethal dose value
REFERENCE :
QJPPAL Quarterly Journal of Pharmacy & Pharmacology. (London, UK) V.2-21,
1929-48. For publisher information, see JPPMAB. Volume(issue)/page/year:
7,205,1934
TYPE OF TE
TYPE OF TEST : DNA damage
TEST SYSTEM : Rodent - hamster Ovary
DOSE/DURATION : 3000 ppm
REFERENCE :
MUREAV Mutation Research. (Elsevier Science Pub. B.V., POB 211, 1000 AE
Amsterdam, Netherlands) V.1- 1964- Volume(issue)/page/year: 367,143,1996
TYPE OF TEST : DNA inhibition
TEST SYSTEM : Rodent - hamster Lung
DOSE/DURATION : 5000 ppm/1H (Continuous)
REFERENCE :
MUREAV Mutation Research. (Elsevier Science Pub. B.V., POB 211, 1000 AE
TYPE OF TEST : DNA damage
ROUTE OF EXPOSURE : Inhalation
TEST SYSTEM : Rodent - mouse
DOSE/DURATION : 4000 ppm/6H (Continuous)
REFERENCE :
CRNGDP Carcinogenesis (London). (Oxford Univ. Press, Pinkhill House,
Southfield Road, Eynsham, Oxford OX8 1JJ, UK) V.1- 1980-
Volume(issue)/page/year: 15,991,1994
TYPE OF TEST : Mutation in microorganisms
TEST SYSTEM : Bacteria - Escherichia coli
DOSE/DURATION : 6300 ppm
REFERENCE :
EMMUEG Environmental and Molecular Mutagenesis. (Alan R. Liss, Inc., 41 E.
11th St., New York, NY 10003) V.10- 1987- Volume(issue)/page/year:
20,211,1992
TYPE OF TEST : Sister chromatid exchange
ROUTE OF EXPOSURE : Inhalation
TEST SYSTEM : Rodent - mouse
DOSE/DURATION : 13880 mg/m3/6H/2W (Intermittent)
REFERENCE :
EMMUEG Environmental and Molecular Mutagenesis. (Alan R. Liss, Inc., 41 E.
11th St., New York, NY 10003) V.10- 1987- Volume(issue)/page/year:
15,221,1990
TYPE OF TEST : Cytogenetic analysis
TEST SYSTEM : Rodent - hamster Ovary
DOSE/DURATION : 6628 mg/L
REFERENCE :
MUREAV Mutation Research. (Elsevier Science Pub. B.V., POB 211, 1000 AE
Amsterdam, Netherlands) V.1- 1964- Volume(issue)/page/year: 116,361,1983
TYPE
TYPE OF TEST : TCLo - Lowest published toxic concentration
ROUTE OF EXPOSURE : Inhalation
SPECIES OBSERVED : Rodent - mouse
DOSE : 1250 ppm/7H
SEX/DURATION : female 6-15 day(s) after conception
TOXIC EFFECTS :
Reproductive - Specific Developmental Abnormalities - musculoskeletal system
REFERENCE :
TXAPA9 Toxicology and Applied Pharmacology. (Academic Press, Inc., 1 E.
First St., Duluth, MN 55802) V.1- 1959- Volume(issue)/page/year:
32,84,1975
TYPE OF TEST : TCLo - Lowest published toxic concentration
ROUTE OF EXPOSURE : Inhalation
SPECIES OBSERVED : Rodent - rat
DOSE : 1250 ppm/7H
SEX/DURATION : female 6-15 day(s) after conception
TOXIC EFFECTS :
Reproductive - Specific Developmental Abnormalities - musculoskeletal system
Reproductive - Specific Developmental Abnormalities - urogenital system
REFERENCE :
TXAPA9 Toxicology and Applied Pharmacology. (Academic Press, Inc., 1 E.
First St., Duluth, MN 55802) V.1- 1959- Volume(issue)/page/year:
32,84,1975
TYPE OF TEST : TCLo - Lowest published toxic concentration
ROUTE OF EXPOSURE : Inhalation
SPECIES OBSERVED : Rodent - rat
DOSE : 4500 ppm/24H
SEX/DURATION : female 1-17 day(s) after conception
TOXIC EFFECTS :
Reproductive - Effects on Newborn - behavioral
REFERENCE :
TXAPA9 Toxicology and Applied Pharmacology. (Academic Press, Inc., 1 E.
First St., Duluth, MN 55802) V.1- 1959- Volume(issue)/page/year:
52,29,1980
Warnings |
危化品目录(2015) |
Restrict |
危险品 |